The Capacity grading system for prismatic lithium power cell is used for the capacity grading of prismatic li-ion cell, which mainly consists of power supply unit, mechanism unit, firefighting system and safety modules.
1.The Introduction of Capacity grading system for prismatic lithium power cell
2.Product Parameter (Specification)
Item | Parameters |
Rated value | 5V60A-5V250A |
Channels | Max. 72CH |
Circuit mode | Recycled switch type charge and discharge |
Charge/discharge voltage range | CC 0.000 ~ 5.000V/DC 1.800 ~ 5.000V |
Voltage accuracy | ±1mV |
Current accuracy | ±0.05%FS |
Measurement period/resolution | 0 ~ 999h/ 1s |
Average charging efficiency | ≥80% |
Average recovery efficiency | ≥75% |
3.Feature And Application of Capacity grading system for prismatic lithium power cell
Module design, probe plate can be easily extracted from the service passage for maintenance.
Ventilation design, power unit with air duct mechanism unit temperature deviation ± 3 degrees C.
Flexible design, tray jacked up to contact pin bed and separated swiftly in case of gas outage or fire accident.
Reliable design, dual-voltage needle, dual-cylinder, cold-rolled terminal to ensure reliable and accurate testing.
Safety protection, with 50 hardware and software protection measures like voltage, capacity, time, system protection etc.
Firefighting design, with isolation fireproof board, smoke sensor, temperature sensor, station explosion-proof curtain, sprinkler system (Novec-1230 fire extinguishing agent and water), to ensure rapid fire response, comprehensive protection and timely fire fighting.
Technical advantages, 15-25% lower energy consumption; charge&discharge efficiency>75%,temperature uniformity <3℃.
4.Qualification of Capacity grading system for prismatic lithium power cell
5.Deliver,Shipping And Serving
1 year warranty
24/7 service
200+ service engineers